The idea behind the imposed solution, is the ability to load pre-calculated hydrodynamic and waterproperties values from hdf5 files. Typically is used to run lagrangian tracers in off-line mode, to run submodels from hydrodynamic and waterproperties hdf5 output windows, to calculate residual fields of velocity and water level, as well as the energy timeserie.

Sample configuration

A typical file for the hydrodyamic_x.dat would be similar to:

EVOLUTION                 : Imposed Solution

<begin_waterlevel>
NAME                      : water level
UNITS                     : m
DIMENSION                 : 2D
DEFAULTVALUE              : 0
INITIALIZATION_METHOD     : hdf
FILE_IN_TIME              : hdf
FILENAME                  : ... (location of the hdf5 file to be imposed)
<end_waterlevel>

<begin_velocity_u>
NAME                      : velocity U
UNITS                     : m/s
DIMENSION                 : 3D
DEFAULTVALUE              : 0
INITIALIZATION_METHOD     : hdf
FILE_IN_TIME              : hdf
FILENAME                  : ... (location of the hdf5 file to be imposed)
<end_velocity_u>

<begin_velocity_v>
NAME                      : velocity V
UNITS                     : m/s
DIMENSION                 : 3D
DEFAULTVALUE              : 0
INITIALIZATION_METHOD     : hdf
FILE_IN_TIME              : hdf
FILENAME                  : ... (location of the hdf5 file to be imposed)
<end_velocity_v>

See also